Files
proxmark3/doc/md/Use_of_Proxmark/1_Validation.md
iceman1001 4eecf9a83c textual
2020-05-21 22:23:12 +02:00

2.8 KiB

1. Validating proxmark client functionality

If all went well you should get some information about the firmware and memory usage as well as the prompt, something like this.

[=] Session log /home/iceman/.proxmark3/log_20200521.txt
[=] Loading Preferences...
[+] loaded from JSON file /home/iceman/.proxmark3/preferences.json
[=] Using UART port /dev/ttyS7
[=] Communicating with PM3 over USB-CDC


██████╗ ███╗   ███╗ ████╗  
██╔══██╗████╗ ████║   ══█║ 
██████╔╝██╔████╔██║ ████╔╝ 
██╔═══╝ ██║╚██╔╝██║   ══█║    :snowflake: iceman@icesql.net
██║     ██║ ╚═╝ ██║ ████╔╝    https://github.com/rfidresearchgroup/proxmark3/
╚═╝     ╚═╝     ╚═╝ ╚═══╝  Release v4.9237 - Ice Coffee :coffee:


 [ Proxmark3 RFID instrument ] 

 [ CLIENT ]
  client: RRG/Iceman/master/v4.9237-2-g2cb19874 2020-05-21 22:00:00
  compiled with GCC 9.3.0 OS:Linux ARCH:x86_64
 
 [ PROXMARK RDV4 ]
  external flash:                  present 
  smartcard reader:                present 

 [ PROXMARK RDV4 Extras ]
  FPC USART for BT add-on support: absent 

 [ ARM ]
 bootrom: RRG/Iceman/master/v4.9237-2-g2cb19874 2020-05-21 22:00:10
      os: RRG/Iceman/master/v4.9237-2-g2cb19874 2019-05-21 22:00:26
 compiled with GCC 8.3.1 20190703 (release) [gcc-8-branch revision 273027]

 [ FPGA ]
 LF image built for 2s30vq100 on 2020/02/22 at 12:51:14
 HF image built for 2s30vq100 on 2020/01/12 at 15:31:16

 [ Hardware ] 
  --= uC: AT91SAM7S512 Rev B
  --= Embedded Processor: ARM7TDMI
  --= Nonvolatile Program Memory Size: 512K bytes, Used: 291382 bytes (56%) Free: 232906 bytes (44%)
  --= Second Nonvolatile Program Memory Size: None
  --= Internal SRAM Size: 64K bytes
  --= Architecture Identifier: AT91SAM7Sxx Series
  --= Nonvolatile Program Memory Type: Embedded Flash Memory


pm3 --> 

This pm3 --> is the Proxmark3 interactive prompt.

To get interactive help

For basic help type help. Or for help on a set of sub commands type the command followed by help. For example hf mf help.

First tests

These commands will return some info about your Proxmark software and hardware status.

pm3 --> hw status
pm3 --> hw version
pm3 --> hw tune

You are now ready to use your newly flashed proxmark3 device. Many commands uses the h parameter to show a help text.

To quit the client

pm3 --> quit

or simple press CTRL-D.

Next steps

Some configuration steps are still needed.

For the next steps, please read the following pages: